190
Source
data
#1 BD board
address
Description
Clock Data
Remark
HD0
ID20000(K0)
Second
0~59
Decimal
HD1
ID20001(K1)
Minute
0~59
Decimal
HD2
ID20002(K2)
Hour
0~23
Decimal
HD3
ID20003(K3)
Date
1~31
Decimal
HD4
ID20004(K4)
Month
1~12
Decimal
HD5
ID20005(K5)
Year
00~99
Decimal
HD6
ID20006(K6)
Week
0 (Sun.)-6 (Sat.)
Decimal
TO command needs to be entered in Sequence Block. The operation procedure is as follows.
In the pop-up window, click "Insert" - "Read/Write Module (FROM/TO)":
In the configuration window that is displayed, set the parameters as follows:
tudonghoatoancau.com

Table of Contents

Other manuals for Xinje XD Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje XD Series and is the answer not in the manual?

Xinje XD Series Specifications

General IconGeneral
Input Voltage24V DC
Storage Temperature-20°C to 70°C
Protection ClassIP20
TypePLC
SeriesXD
Programming LanguageLadder Logic, Instruction List
Communication InterfaceRS232, RS485
Power Supply24V DC
Digital InputsAvailable (number varies by model)
Digital OutputsAvailable (number varies by model)
Analog InputsAvailable (number varies by model)
Analog OutputsAvailable (number varies by model)
Output TypeRelay, Transistor
Number of InputsVaries by model (see Digital Inputs and Analog Inputs)
Number of OutputsVaries by model (see Digital Outputs and Analog Outputs)
Operating Temperature0°C to 50°C
Humidity5% to 95% (non-condensing)