372
K0: stop the BLOCK slowly, if the pulse is outputting, the BLOCK will stop after the pulse
outputting is finished.
K1: stop the BLOCK immediately; stop all the instructions running in the BLOCK.
K2: Destructive slow stop BLOCK, that is, when the pulse is being sent, the SBSTOP
condition holds, then the pulse will slow down along the slope, without to use with the
SBGOON instruction, so the remaining instructions will not be executed. After executing this
instruction, the BLOCK can be restarted. (Note: K2 mode is only supported by V3.4.2 and
above PLC)
Continue running the BLOCK[SBGOON]
1)Summary
This instruction is opposite to SBSTOP. To continue running the BLOCK.
[SBGOON]
16 bits
SBGOON
32 bits
-
Condition
Pulse edge
Suitable
types
XD, XL
Hardware
-
Software
V3.2
2)Operands
Operand
Function
Type
S1
The number of the BLOCK
16 bits, BIN
S2
The mode to continue running the BLOCK
16 bits, BIN
3)Suitable component
Operands
Word soft elements
Bit soft elements
System
Consta
nt
Module
System
D
F
D
T
D
C
D
D
X
D
Y
D
M
D
S
K/H
I
D
Q
D
X
Y
M
S
T
C
Dn.
m
S1
S2
*Notes: D includes D, HD; TD includes TD, HTD; CD includes CD, HCD, HSCD, HSD; DM
includes DM, DHM; DS includes DS, DHS. M includes M,HM,SMS includes S,HST
includes T,HTC includes C, HC.