408
counter is HSC0), the width of each workpiece is 100, the distance between workpieces is
1500, the distance between workpieces is 1000, the distance between workpieces is X4, 2000,
and the distance between workpieces is 4000.
The procedure is as follows:
Output result address assignment:
Soft component address
Function description
X4
Trigger input point
HSC0
High speed counting input point, receiving encoder signal
HD0
Number of stations, HD0=3 in the example
HD1
The maximum number of workpieces that can be
processed , HD1=4 in the example
HD2
Filter timeHD2=300ms in the example
HD10(double word)
The reference value of station 1.HD10=1000 here in the
example
HD12(double word)
The reference value of station 2.HD12=2000 here in the
example
HD14(double word)
The reference value of station 3.HD14=4000 here in the
example
HD16(double word)
The workpiece of station 1 enters the deviation value and
is set to 0
HD18(double word)
The workpiece of station 2 enters the deviation value and
is set to 0
HD20(double word)
The workpiece of station 3 enters the deviation value and
is set to 0
HD22(double word)
The workpiece departure deviation value of station 1 is set
to 0
HD24(double word)
The workpiece departure deviation value of station 2 is set
to 0
HD26(double word)
The workpiece departure deviation value of station 3 is set
to 0
Name
Station 1
Station 2
Station 3
Forward index
value(single word)
HD100
HD101
HD102
Follow index value(single
word)
HD103
HD104
HD105
Workpiece 1 enters the
comparison value(double
word)
HD106
HD108
HD110
tudonghoatoancau.com