E.3 User Setting Table
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual 525
Quick Reference
Sheet
E
C4-02 Torque Compensation Primary Delay Time
C4-03 Torque Compensation at Forward Start
C4-04 Torque Compensation at Reverse Start
C4-05 Torque Compensation Time Constant
C4-06 Torque Compensation Primary Delay Time 2
C4-07 Motor 2 Torque Compensation Gain
C5-01 ASR Proportional Gain 1
C5-02 ASR Integral Time 1
C5-03 ASR Proportional Gain 2
C5-04 ASR Integral Time 2
C5-05 ASR Limit
C5-06 ASR Primary Delay Time Constant
C5-07 ASR Gain Switching Frequency
C5-08 ASR Integral Limit
C5-12 Integral Operation during Accel/Decel
C5-17 Motor Inertia
C5-18 Load Inertia Ratio
C5-21 Motor 2 ASR Proportional Gain 1
C5-22 Motor 2 ASR Integral Time 1
C5-23 Motor 2 ASR Proportional Gain 2
C5-24 Motor 2 ASR Integral Time 2
C5-25 Motor 2 ASR Limit
C5-26 Motor 2 ASR Primary Delay Time Constant
C5-27 Motor 2 ASR Gain Switching Frequency
C5-28 Motor 2 ASR Integral Limit
C5-32 Integral Operation during Accel/Decel for Motor 2
C5-37 Motor 2 Inertia
C5-38 Motor 2 Load Inertia Ratio
C6-01 Drive Duty Selection
C6-02 Carrier Frequency Selection
C6-03 Carrier Frequency Upper Limit
C6-04 Carrier Frequency Lower Limit
C6-05 Carrier Frequency Proportional Gain
C6-09 Carrier Frequency during Rotational Auto-Tuning
d1-01 Frequency Reference 1
d1-02 Frequency Reference 2
d1-03 Frequency Reference 3
d1-04 Frequency Reference 4
d1-05 Frequency Reference 5
d1-06 Frequency Reference 6
d1-07 Frequency Reference 7
d1-08 Frequency Reference 8
d1-09 Frequency Reference 9
d1-10 Frequency Reference 10
d1-11 Frequency Reference 11
d1-12 Frequency Reference 12
d1-13 Frequency Reference 13
d1-14 Frequency Reference 14
d1-15 Frequency Reference 15
d1-16 Frequency Reference 16
d1-17 Jog Frequency Reference
d2-01 Frequency Reference Upper Limit
d2-02 Frequency Reference Lower Limit
d2-03 Master Speed Reference Lower Limit
d3-01 Jump Frequency 1
d3-02 Jump Frequency 2
d3-03 Jump Frequency 3
d3-04 Jump Frequency Width
d4-01 Frequency Reference Hold Function Selection
d4-03 Frequency Reference Bias Step (Up/Down 2)
d4-04 Frequency Reference Bias Accel/Decel (Up/Down 2)
d4-05
Frequency Reference Bias Operation Mode Selection (Up/
Down 2)
d4-06 Frequency Reference Bias (Up/Down 2)
d4-07
Analog Frequency Reference Fluctuation Limit (Up/Down
2)
No. Name
User
Setting
d4-08 Frequency Reference Bias Upper Limit (Up/Down 2)
d4-09 Frequency Reference Bias Lower Limit (Up/Down 2)
d4-10 Up/Down Frequency Reference Limit Selection
d4-11 Bi-directional Output Selection
d4-12 Stop Position Gain
d5-01 Torque Control Selection
d5-02 Torque Reference Delay Time
d5-03 Speed Limit Selection
d5-04 Speed Limit
d5-05 Speed Limit Bias
d5-06 Speed/Torque Control Switchover Time
d5-08 Unidirectional Speed Limit Bias
d6-01 Field Weakening Level
d6-02 Field Weakening Frequency Limit
d6-03 Field Forcing Selection
d6-06 Field Forcing Limit
d7-01 Offset Frequency 1
d7-02 Offset Frequency 2
d7-03 Offset Frequency 3
E1-01 Input Voltage Setting
E1-03 V/f Pattern Selection
E1-04 Maximum Output Frequency
E1-05 Maximum Voltage
E1-06 Base Frequency
E1-07 Middle Output Frequency
E1-08 Middle Output Frequency Voltage
E1-09 Minimum Output Frequency
E1-10 Minimum Output Frequency Voltage
E1-11 Middle Output Frequency 2
E1-12 Middle Output Frequency Voltage 2
E1-13 Base Voltage
E2-01 Motor Rated Current
E2-02 Motor Rated Slip
E2-03 Motor No-Load Current
E2-04 Number of Motor Poles
E2-05 Motor Line-to-Line Resistance
E2-06 Motor Leakage Inductance
E2-07 Motor Iron-Core Saturation Coefficient 1
E2-08 Motor Iron-Core Saturation Coefficient 2
E2-09 Motor Mechanical Loss
E2-10 Motor Iron Loss for Torque Compensation
E2-11 Motor Rated Power
E3-01 Motor 2 Control Mode Selection
E3-04 Motor 2 Maximum Output Frequency
E3-05 Motor 2 Maximum Voltage
E3-06 Motor 2 Base Frequency
E3-07 Motor 2 Mid Output Frequency
E3-08 Motor 2 Mid Output Frequency Voltage
E3-09 Motor 2 Minimum Output Frequency
E3-10 Motor 2 Minimum Output Frequency Voltage
E3-11 Motor 2 Mid Output Frequency 2
E3-12 Motor 2 Mid Output Frequency Voltage 2
E3-13 Motor 2 Base Voltage
E4-01 Motor 2 Rated Current
E4-02 Motor 2 Rated Slip
E4-03 Motor 2 Rated No-Load Current
E4-04 Motor 2 Motor Poles
E4-05 Motor 2 Line-to-Line Resistance
E4-06 Motor 2 Leakage Inductance
E4-07 Motor 2 Motor Iron-Core Saturation Coefficient 1
E4-08 Motor 2 Motor Iron-Core Saturation Coefficient 2
E4-09 Motor 2 Mechanical Loss
E4-10 Motor 2 Iron Loss
E4-11 Motor 2 Rated Power
E5-01 Motor Code Selection
No. Name
User
Setting

Table of Contents

Other manuals for YASKAWA A1000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA A1000 Series and is the answer not in the manual?

YASKAWA A1000 Series Specifications

General IconGeneral
SeriesA1000
TypeAC Drive
AltitudeUp to 1000m without derating
Output Frequency0-400 Hz
Control MethodV/f Control
Overload Capacity150% for 60 seconds
Communication OptionsModbus, DeviceNet, Profibus, Ethernet/IP
Ambient Temperature-10 to 50°C
Storage Temperature-20 to 60°C
Humidity5% to 95% (non-condensing)
Enclosure RatingIP20
Horsepower0.5 to 1000 HP
Power Range0.4 - 630 kW (varies by voltage and model)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
Cooling MethodFan Cooled
SafetySafe Torque Off (STO)