8Alarm
DX100 8.3 Alarm Message List
8-559
4652 TRQ MEASURE
MODE SET
ERR(SV)
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4653 TRQ MEASURE
MODE CANCEL
ERR(SV)
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4654 WRONG
EXECUTION OF
SETREG INST
1 An attempt was made to change
the value of the register currently
used by TMR/CNT.
Setting error (1)Check the following settings.
·The SETREGM instruction cannot change the register values used in TMR/
CNT. Correct the setting of tag that specifies register number of SETREG
instruction.
4655 WRONG
EXECUTION OF
GETREG INST
1 An attempt was made to acquire
the value of the register not
existing.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4656 WRONG
EXECUTION OF
SETPRM INST
1 An attempt was made to change a
parameter other than the cube-
related parameter.
Setting error (1)Check the following settings.
·The SETPRM instruction cannot change the parameter values other than
the parameter related to the cube. Correct the setting of tag that specifies
parameter number of SETPRM instruction.
2 The SETPRM instruction was
executed while another system
was in execution.
Setting error (1)Check the following settings.
·The SETPRM instruction cannot execute while another system is operating.
Correct the job.
4657 WVADJ ERROR 1 The correction amplitude value did
not fall in the limit range.
Setting error (1)Check the following settings.
·Correct the settings for "groove width correction limit value" specified for
S2C1259 and 1260.
Alarm
Number
Alarm Name Sub
Code