10.5 Motion Parameter Details
10.5.3 Monitor Parameter List
10-52
IW0D
Input Data
Option Selec-
tion Monitor
Bit 0: Motor Speed
ON when Motor Speed is selected for Input Data
Option Selection (OW0D) and the data is
being normally reported.
Bit 1: Torque Reference
ON when Torque Reference is selected for Input
Data Option Selection (OW0D) and the
data is being normally reported.
Bit 2: Encoder Count PG1
ON when Encoder Count PG1 is selected for
Input Data Option Selection (OW0D) and
the data is being normally reported.
Bit 3: Frequency Refer-
ence
ON when Frequency Reference is selected for
Input Data Option Selection (OW0D) and
the data is being normally reported.
Bit 4: Analog Input A2
ON when Analog Input A2 is selected for Input
Data Option Selection (OW0D) and the
data is being normally reported.
Bit 5: Main Bus Voltage
ON when Main Bus Voltage is selected for Input
Data Option Selection (OW0D) and the
data is being normally reported.
Bit 6: Alarm Code
ON when Alarm Code is selected for Input Data
Option Selection (OW0D) and the data is
being normally reported.
Bit 7: Warning Code
ON when Warning Code is selected for Input
Data Option Selection (OW0D) and the
data is being normally reported.
Bit 8: Multi-Function Out-
put Terminal
ON when Multi-Function Output Terminal is
selected for Input Data Option Selection
(OW0D) and the data is being normally
reported.
Bit 9: Analog Input A3
ON when Analog Input A3 is selected for Input
Data Option Selection (OW0D) and the
data is being normally reported.
Bit A: Multi-Function Input
Term i nal
ON when Multi-Function Input Terminal is
selected for Input Data Option Selection
(OW0D) and the data is being normally
reported.
Bit B: Analog Input A1
ON when Analog Input A1 is selected for Input
Data Option Selection (OW0D) and the
data is being normally reported.
Bit C: Encoder Count PG2
ON when Encoder Count PG2 is selected for
Input Data Option Selection (OW0D) and
the data is being normally reported.
Bit D: Monitor data set in
F6-23
ON when
Monitor Data Set in F6
-23 is selected
for Input Data Option Selection (OW0D)
and the data is being normally reported.
Bit E: Monitor data set in
F6-24
ON when Monitor Data Set in F6-24 is selected
for Input Data Option Selection (OW0D)
and the data is being normally reported.
Bit F Reserved
IW
0E − Reserved
Continued on next page.
Continued from previous page.
Register
No.
Name Description