EasyManua.ls Logo

YASKAWA SVC - Motion Control Program Commands and Instructions; 4.1 Commands; 4.2 Motion Command Details; 4.3 Motion Subcommand Details

YASKAWA SVC
623 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.3 Motion Parameter Tables
3.3.3 Monitor Parameter Table
3-22
IW09
Motion Com-
mand Status
Bit 0: Command Execution Flag (BUSY)
0: READY (Completed)
1: BUSY (Processing)

page 3-74
Bit 1: Command Hold Completed
(HOLDL)
0: Command hold not completed
1: Command hold completed

Bit 2: Reserved.
Bit 3: Command Error End (FAIL)
(Command error completed status)
0: Completed normally
1: Completed with an error

Bits 4 to 6: Reserved.
Bit 7: Absolute Encoder Reset Com-
pleted (ABS_RSTC)
0: Reset not completed
1: Reset completed
Bit 8: Command Execution Completed
(COMPLETE)
0: Normal execution not completed
1: Normal execution completed

Bits 9 to F: Reserved.
IW
0A
Motion Sub-
command
Response Code
Same as OW0A (Motion Subcom-
mands).
page 3-75
IW
0B
Motion Sub-
command Sta-
tus
Bit 0: Command Execution Flag
0: READY (Completed)
1: BUSY (Processing)

page 3-75
Bits 1 to 2: Reserved.
Bit 3: Command Error End
(Command error completed status)
0: Completed normally
1: Completed with an error

Bits 4 to 7: Reserved.
Bit 8: Command Execution Completed
0: Normal execution not completed
1: Normal execution completed

Bits 9 to F: Reserved.
Continued on next page.
Continued from previous page.
Register
Address
Name Description
SVC
Function
Module
SVR
Function
Module
Reference
Page

Table of Contents

Related product manuals