8-15
IM 701240-01E
3
2
1
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
App
Index
Waveform Display and Information Display
Number of Data Points to Be Used for Waveform Display
Same as “Number of Data Points to Be Used for Waveform Display” described in section
8.2.
See section 8.2.
X-Y Waveform Display Range (Start Point/End Point)
The X-Y display shows the range selected on the T-Y waveform.
You can set the start (fine dashed line) and end (coarse dashed line) positions in the
range of –5 to +5 divisions from the center of the waveform display frame. The start and
end points are not displayed if only X-Y waveforms are displayed.
The resolution is as follows:
Resolution: Record time ÷ record length
Notes on Displaying X-Y Waveforms
The divided windows of the T-Y waveform display when using the T-Y & X-Y mode
are displayed according to Format in the DISPLAY menu.
The zoom function applies only to T-Y waveforms. In addition, Main, Z1, or Z2 can be
selected for the T-Y waveform.
To expand the X-Y waveform, change Upper and Lower settings or V Zoom of each
channel. The displayed waveform can be expanded/reduced.
To change the display position of the X-Y waveform, change the position of each
channel. (For voltage input)
X-Y waveform is not displayed when the horizontal axis of a waveform trace is in units
of time and the horizontal axis of another waveform trace is in units of frequency.
Logic waveforms are not applicable to X-Y waveform display.
8.6 Displaying X-Y Waveforms