7 - 8 DS457-XX20004ZZWW Fixed Mount Imager Integration Guide
Low Light Enhancement
Parameter # 612 (SSI # F1h 64h)
In Presentation Mode, selecting Enable Low Light Enhancement causes illumination to remain on at low
power in low lighting conditions. When the imager detects an object in its field of view, it turns on illumination
full power. Select Disable Low Light Enhancement to prevent illumination from remaining on under low
lighting conditions
Power Up Light in Presentation Mode
Parameter # 1198 (SSI # F8h 04h AEh)
Scan Enable Power Up Light in Presentation Mode to turn on full illumination upon power-up when in
presentation mode or transitioning to presentation mode. If Low Light Enhancement is also enabled,
illumination turns on at low power in presentation mode. If both are disabled, illumination remains off until
motion is detected.
Enable Low Light Enhancement
(1)
*Disable Low Light Enhancement
(0)
Enable Power Up Light in Presentation Mode
(1)
*Disable Power Up Light in Presentation Mode
(0)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS457 Series and is the answer not in the manual?

Zebra DS457 Series Specifications

General IconGeneral
ConnectivityUSB, RS-232
Decode Capability1D, 2D, PDF417, Postal Codes
Scan RateUp to 60 scans per second
Supported Barcode TypesUPC/EAN, Code 39, Code 128, QR Code, Data Matrix, PDF417, Postal Codes
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Humidity5% to 95% (non-condensing)
Power Consumption2.5 W (typical)