EasyManuals Logo
Home>Zebra>Barcode Reader>DS457 Series

Zebra DS457 Series User Manual

Zebra DS457 Series
462 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #81 background imageLoading...
Page #81 background image
User Preferences 6 - 17
Picklist Mode
Parameter # 402 (SSI # F0h 92h)
Picklist mode enables the imager to decode only bar codes aligned under the center of the laser aiming
pattern. Select one of the following picklist modes:
Disabled Always - Picklist mode is always disabled.
Enabled Always - Picklist mode is always enabled.
Decode Session Timeout
Parameter # 136 (SSI # 88h)
This parameter sets the maximum time decode processing continues during a scan attempt. It is
programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds.
To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from Appendix
G, Numeric Bar Codes that correspond to the desired on time. Provide a leading zero for single digit numbers.
For example, to set a Decode Session Timeout of 0.5 seconds, scan the bar code below, then scan the 0 and
5 bar codes. To correct an error or change the selection, scan Cancel on page G-3.
NOTE With Picklist Mode enabled, the decode aiming pattern turns on even when the Decode Aiming Pattern on
page 7-6 is disabled.
Picklist mode does not apply to OCR reading.
*Disabled Always
(0)
Enabled Always
(2)
Decode Session Timeout

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS457 Series and is the answer not in the manual?

Zebra DS457 Series Specifications

General IconGeneral
BrandZebra
ModelDS457 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals