12 - 82 DS457-XX20004ZZWW Fixed Mount Imager Integration Guide
GS1 DataBar Expanded
Parameter # 340 (SSI # F0h 54h)
Scan the appropriate bar code below to enable or disable the following code types:
GS1 DataBar Expanded
GS1 DataBar Expanded Stacked
Convert GS1 DataBar to UPC/EAN
Parameter # 397 (SSI # F0h, 8Dh)
This parameter only applies to GS1 DataBar Omnidirectional and GS1 DataBar Limited symbols not decoded
as part of a Composite symbol. Enable this to strip the leading '010' from GS1 DataBar Omnidirectional and
GS1 DataBar Limited symbols encoding a single zero as the first digit, and report the bar code as EAN-13.
For bar codes beginning with two or more zeros but not six zeros, this parameter strips the leading '0100' and
reports the bar code as UPC-A. The UPC-A Preamble parameter that transmits the system character and
country code applies to converted bar codes. Note that neither the system character nor the check digit can be
stripped.
*Enable GS1 DataBar Expanded
(1)
Disable GS1 DataBar Expanded
(0)
Enable Convert GS1 DataBar to UPC/EAN
(1)
*Disable Convert GS1 DataBar to UPC/EAN
(0)