12 - 90 DS457-XX20004ZZWW Fixed Mount Imager Integration Guide
Code 128 Emulation
Parameter # 123 (SSI # 7Bh)
When this parameter is enabled, the imager transmits data from certain MicroPDF417 symbols as if it was
encoded in Code 128 symbols. Transmit AIM Symbology Identifiers must be enabled for this parameter to
work.
If Code 128 Emulation is enabled, these MicroPDF417 symbols are transmitted with one of the following
prefixes:
]C1 if the first codeword is 903-905
]C2 if the first codeword is 908 or 909
]C0 if the first codeword is 910 or 911
If disabled, they are transmitted with one of the following prefixes:
]L3 if the first codeword is 903-905
]L4 if the first codeword is 908 or 909
]L5 if the first codeword is 910 or 911
Scan a bar code below to enable or disable Code 128 Emulation.
NOTE Linked MicroPDF codewords 906, 907, 912, 914, and 915 are not supported. Use GS1 Composites
instead.
Enable Code 128 Emulation
(1)
*Disable Code 128 Emulation
(0)