12 - 36 DS457-XX20004ZZWW Fixed Mount Imager Integration Guide
Code 128 Reduced Quiet Zone
Parameter # 1208 (SSI # F8h 04h B8h)
Scan one of the following bar codes to enable or disable decoding Code 128 bar codes with reduced quiet
zones. If you select Enable, select a 1D Quiet Zone Level on page 12-105.
Ignore Code 128 <FNC4>
Parameter # 1254 (SSI # F8h 04h E6h)
This feature applies to Code 128 bar codes with an embedded <FNC4> character. Enable this to strip the
<FNC4> character from the decode data. The remaining characters are sent to the host unchanged. When
disabled, the <FNC4> character is processed normally as per Code 128 standard.
Enable Code 128 Reduced Quiet Zone
(1)
*Disable Code 128 Reduced Quiet Zone
(0)
Enable Ignore Code 128 <FNC4>
(1)
*Disable Ignore Code 128 <FNC4>
(0)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS457 Series and is the answer not in the manual?

Zebra DS457 Series Specifications

General IconGeneral
ConnectivityUSB, RS-232
Decode Capability1D, 2D, PDF417, Postal Codes
Scan RateUp to 60 scans per second
Supported Barcode TypesUPC/EAN, Code 39, Code 128, QR Code, Data Matrix, PDF417, Postal Codes
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Humidity5% to 95% (non-condensing)
Power Consumption2.5 W (typical)

Related product manuals