11 - 20 DS457-XX20004ZZWW Fixed Mount Imager Integration Guide
New Line (E)
To create a template of multiple lines, add E between the template of each single line.
Template Valid data Valid data Invalid data
999EAAAA 321 987 XYZW
BCAD ZXYW 12
String Extract (C)
This operator combined with others defines a string of characters to extract from the scanned data. The string
extract is structured as follows:
CbPe
Where:
C is the string extract operator
b is the string begin delimiter
P is a single template character representing all string characters to be extracted
e is the string end delimiter
Values for b and e can be any scannable character. They are included in the output stream.
Template Incoming data Output
C>A> XQ3>ABCDE> >ABCDE>
->ATHRUZ>123 >ATHRUZ>
1ABCZXYZ No Output
E
C

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS457 Series and is the answer not in the manual?

Zebra DS457 Series Specifications

General IconGeneral
ConnectivityUSB, RS-232
Decode Capability1D, 2D, PDF417, Postal Codes
Scan RateUp to 60 scans per second
Supported Barcode TypesUPC/EAN, Code 39, Code 128, QR Code, Data Matrix, PDF417, Postal Codes
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Humidity5% to 95% (non-condensing)
Power Consumption2.5 W (typical)