Datawedge Configuration
116
Reader Params
Allows the configuration of parameters specific to the selected barcode reader.
• 1D Quiet Zone Level - Sets the level of aggressiveness in decoding barcodes with a reduced quiet zone
(the area in front of and at the end of a barcode), and applies to symbologies enabled by a Reduced Quiet
Zone parameter. Because higher levels increase the decoding time and risk of misdecodes, Zebra strongly
recommends enabling only the symbologies which require higher quiet zone levels, and leaving Reduced
Quiet Zone disabled for all other symbologies. (SE4750-SR and SE4850-ER).
Options are:
• 0 - The scanner performs normally in terms of quiet zone.
• 1 - The scanner performs more aggressively in terms of quiet zone (default).
• 2 - The scanner only requires one side EB (end of barcode) for decoding.
• 3 - The scanner decodes anything in terms of quiet zone or end of barcode.
• Aim mode - Turns the scanner cross-hairs on or off. (SE4750-SR and SE4850-ER)
• On - Cross-hair is on (default).
• Off - Cross-hair is off.
• Adaptive Scanning - When adaptive scanning is enabled, the scan engine toggles between wide and
narrow, allowing the scan engine to decode barcodes based on the distance. (SE965).
• Disable
• Enable (default).
• Beam Width - Beam Width is applicable only with linear scanners. (SE965)
• Narrow
• Normal (default)
• Wide
• Character Set Selection - (SE965, SE4750-SR, and SE4850-ER).
• ISO-88959-1 - part of the ISO/IEC 8859 series of ASCII-based standard character encodings. It is
generally intended for Western European languages.
• Shift_JIS - Shift Japanese Industrial Standards (JIS) is a character encoding for the Japanese
language.
• UTF-8 - A character encoding capable of encoding all possible characters, or code points, defined by
Unicode (default).
• Time Delay to Low Power - Sets the time the decoder remains active after decoding. After a scan
session, the decoder waits this amount of time before entering Low Power Mode. Options: 1 Second
(default), 30 Seconds, 1 Minute or 5 Minutes (SE965, RS507/RS507X, and RS6000).
• Illumination Brightness - Sets the brightness of the illumination by altering LED power. The default is 10,
which is maximum LED brightness. For values from 1 to 10, LED brightness varies from lowest to highest
level of brightness (RS507/RS507X and RS6000).
• Illumination mode - Turns imager illumination on and off. This option is only available when Bluetooth
Scanner is selected in the Barcode input, Scanner selection option. (SE4750-SR, and SE4850-ER)
• Off - Illumination is off.
• On - Illumination is on (default).