Datawedge Configuration
118
• Different Symbol Timeout - Controls the time the scanner is inactive between decoding different
symbols. Programmable in 500 msec increments from 0 to 5 seconds. The default is 500 msec.
• Same Symbol Timeout - Controls the time the scanner is inactive between decoding same symbols.
Programmable in 500 msec increments from 0 to 5 seconds. The default is 500 msec.
• Scanning Modes - Scanning options available on the device. (SE4750-SR and SE4850-ER).
• Single - Set to scan general barcodes (default).
• UDI - Set to scan healthcare specific barcodes,
Scan Params
Allows the configuration of Code ID and decode feedback options.
• Code ID Type - A Code ID character identifies the code type of a scanned barcode. This is useful when
the reader is decoding more than one code type. Select a code ID character to insert between the prefix
and the decoded symbol.
• Code ID Type None - No prefix (default)
• Code ID Type AIM - Insert AIM Character prefix.
• Code ID Type Symbol - Insert Symbol character prefix.
• Engine Decode LED - Use to turn on scanner red LED when the scan beam is emitting either by scanner
trigger or using soft scan button (RS507/RS507X).
• BT Disconnect On Exit - Bluetooth connection is disconnected when data capture application is closed
(RS507/RS507X, RS6000 and DS3678).
• Connection Idle Time - Set connection idle time. The Bluetooth connection disconnects after being idle
for set time (RS507/RS507X, RS6000 and DS3678).
• Display BT Address Barcode - Enable or disable displaying Bluetooth Address bar code if there is no
Bluetooth scanner being paired when application tries to enable the Bluetooth scanner (RS507/RS507X
and RS6000).
• Establish Connection Time - The timeout which the device will try to enable or reconnect to the Bluetooth
scanner when the Bluetooth scanner is not in the vicinity or not paired (RS507/RS507X and RS6000).
• Audio Feedback Mode - Select good decode audio indication (RS507/RS507X, RS6000, and DS3678).
• Local Audio Feedback - Good decode audio indication on MC33XX only.
• Remote Audio Feedback - Good decode audio indication on RS507/RS507X, RS6000, and DS3678.
• Both - Good decode audio indication on MC33XX and RS507/RS507X, RS6000, and DS3678)
(default).
• Disable - No good decode audio indication on either MC33XX or RS507/RS507X, RS6000, and
DS3678).
• LED Feedback Mode - Select good decode LED indication (RS507/RS507X, RS6000, and DS3678).
• Local LED Feedback - Good decode LED indication on MC33XX only.
• Remote LED Feedback - Good decode LED indication on RS507/RS507X, RS6000, and DS3678.
• Both - Good decode LED indication on MC33XX and RS507/RS507X, RS6000, and DS3678 (default).
• Disable - No good decode LED indication on either MC33XX or RS507/RS507X, RS6000, and
DS3678.
• Decode Audio Feedback - Select an audio tone to sound upon a good decode (default optimized-beep).
• Decoding LED Notification - Enable the device to light the red Data Capture LED when data capture is in
progress. (default - disabled).