AutoTest Sytem Operation
Subject to Export Control, see Cover Page for details.
5-14
Set Commands (cont)
set_fgen_ch1_enable [ state 0/1 ]
Turns AF Generator 2 ON or OFF.
Valid states are:
0 = OFF
1 = ON
set_fgen_ch1_type [ shape 0 ]
Sets AF Generator 2 waveform shape.
Valid shapes are:
0 = Sine
set_fgen_ch2_freq [ freq in Hz ]
Sets AF Generator 3 frequency.
Format: Frequency in Hz as parameter
set_fgen_ch2_level [ level in Vrms ]
Sets AF Generator 3 level.
Format: Decimal level value in Vrms
set_fgen_ch2_enable [ state 0/1 ]
Turns AF Generator 3 ON or OFF.
Valid states are:
0 = OFF
1 = ON
set_fgen_ch2_type [ shape 0 ]
Sets AF Generator 3 waveform shape.
Valid shapes are:
0 = Sine
set_audio_filter [ type 0 - 7 ]
Sets Audio input filter type.
Valid types are:
0 = None
1 = PSOPH
2 = 300 Hz LP
3 = 5 kHz LP
4 = 20 kHz LP
5 = 0.3 - 3.4 kHz
6 = 0.3 - 5 kHz
7 = 0.3 - 20 kHz
8 = 300 Hz HP
set_audio_freq_ulimit [ limit Hz ]
Sets upper limit for audio frequency measurements.
Format: Decimal limit value in Hz