AutoTest Sytem Operation
Subject to Export Control, see Cover Page for details.
5-15
Set Commands (cont)
set_audio_freq_ulen [ state 0/1 ]
Enables/Disables the upper limit check on audio frequency measurements.
Valid states are:
0 = Disabled
1 = Enabled
set_audio_freq_llimit [ limit Hz ]
Sets lower limit for audio frequency measurements.
Format: Decimal limit value in Hz
set_audio_freq_llen [ state 0/1 ]
Enables/Disables lower limit check on audio frequency measurements.
Valid states are:
0 = Disabled
1 = Enabled
set_audio_port [ type 0 - 6 ]
Sets fgen/demod output port to various types.
Valid types are:
0 = Function Generator
1 = Audio In
2 = Audio In Filtered
3 = Demod
4 = Demod De-emphasis
5 = Demod Filtered
6 = Demod De-emphasis Filtered
set_audio_impedance [ load 0/1 ]
Sets audio input impedance.
Valid values are:
0 = Hi Z
1 = 600 Ohms
set_audio_source [ source 0 - 3 ]
Sets audio input source.
Valid sources are:
0 = Audio 1
1 = Audio 2
2 = Balanced
3 = MIC
set_audio_psoph_filter [ type 0/1 ]
Sets audio psoph filter type to CMESS or CCITT.
Valid sources are:
0 = CMESS