AutoTest Sytem Operation
Subject to Export Control, see Cover Page for details.
5-16
Config Commands
set_audio_freq_average
Sets number of averages used to calculate measurement.
Format: Whole numbers
Range: 1 to 250
set_audio_level_average
Sets number of averages used to calculate measurement.
Format: Whole numbers
Range: 1 to 250
set_audio_level_ulimit [ limit Vrms ]
Sets upper limit for aflevel meter.
Format: Decimal limit value in Vrms
set_audio_level_ulen [ state 0/1 ]
Enables/Disables the upper limit check on aflevel meter.
Valid states are:
0 = Disabled
1 = Enabled
set_audio_level_llimit [ limit Vrms ]
Sets lower limit for aflevel meter.
Format: Decimal limit value in Vrms
set_audio_level_llen [ state 0/1 ]
Enables/Disables lower limit check on aflevel meter.
Valid states are:
0 = Disabled
1 = Enabled
set_audio_distortion_average
Sets number of averages used to calculate measurement.
Format: Whole numbers
Range: 1 to 250
set_audio_distortion_ulimit [ limit % ]
Sets upper limit for afdistortion meter.
Format: Decimal limit value as a percent
set_audio_distortion_ulen [ state 0/1 ]
Enables/Disables upper limit check on afdistortion meter.
Valid states are:
0 = Disabled
1 = Enabled
set_audio_sinad_average
Sets number of averages used to calculate measurement.
Format: Whole numbers
Range: 1 to 250