EasyManua.ls Logo

Aeroflex 3901 - Page 115

Aeroflex 3901
301 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AutoTest Sytem Operation
Subject to Export Control, see Cover Page for details.
5-19
Set Commands
set_amfmmod_mod0_freq [ freq in kHz]
Sets Modulator 1 frequency.
Format: Decimal frequency in kHz
Range: 0.001 to 20 kHz
set_amfmmod_mod0_devper [ kHz or % ]
Sets level/amplitude for Modulator 1.
FM:
Level/Amplitude is displayed in kHz
Range: 0.001 to 150 kHz
AM:
Level/Amplitude is displayed as %
Range: 0.1 to 100%
AM USB:
Level/Amplitude is displayed as %
Range: 0.1 to 100%
AM LSB:
Level/Amplitude is displayed as %
Range: 0.1 to 100%
Format: Decimal values
set_amfmmod_mod0_type [ 0 = Sine ]
Sets waveform shape for Modulator 1.
Default is 0 = Sine.
set_amfmmod_mod0_enable [ 0/1 ]
Turns modulation source for Modulator 1 ON/OFF.
Valid values are:
0 = OFF
1 = ON
set_amfmmod_mod1_freq [ freq in kHz ]
Sets Modulator 2 frequency.
Format: Decimal frequency value in kHz
Range: 0.001 to 20 kHz