AutoTest Sytem Operation
Subject to Export Control, see Cover Page for details.
5-34
Set Commands (cont)
set_scope_markermode [ state 0/1 ]
Lock/Unlock markers when both are enabled.
Valid states are:
0 = Unlocked
1 = Locked
set_scope_marker1ulimit
Sets scope marker upper limit.
Format: Decimal limit value as follows based on Marker source:
Source CH1, CH2 or Audio:
Parameter is mV when Vertical Level <
200 mV
Parameter is V when Vertical Level >200 V
Source FM Demod:
Parameter is Hz when Vertical Level is 500 Hz, otherwise kHz
Source AM Demod:
Parameter is a %
set_scope_marker1ulen [ state 0/1 ]
Enables/Disables the upper limit check on the Oscilloscope
Valid states are:
0 = Disabled
1 = Enabled
set_scope_marker1llimit
Sets scope marker lower limit.
Format: Decimal limit value as follows based on Marker source:
Source CH1, CH2 or Audio:
Parameter is mV when Vertical Level <
200 mV
Parameter is V when Vertical Level >200 V
Source FM Demod:
Parameter is Hz when Vertical Level is 500 Hz, otherwise kHz
Source AM Demod:
Parameter is a %
set_scope_marker1llen [ state 0/1 ]
Enables/Disables the lower limit check on the Oscilloscope.
Valid states are:
0 = Disabled
1 = Enabled