VCore Page 127
VCore
Digital Outputs
Configuring Outputs
The VCore provides 4 Dry-Contact Relay Outputs for discrete control. The initial state of each output may
be configured by WinScript Live to be open or closed when the script is started.
The back panel outputs are configured by WinScript Live software. Select Resources command from the
main menu bar then select Outputs. The window shown below opens. You may change the name, define
the initial state of the output, and add a comment to describe the output’s use.
Output Connector
Note The Relay Outputs are fused at 900mA using self-restoring polymer fuses. If an
overload occurs, the fuse will open until the problem is corrected; then it will heal itself.
Pin
Connection
Pin
Connection
1
Output 1
5
Output 1 Return
2
Output 2
6
Output 2 Return
3
Output 3
7
Output 3 Return
4
Output 4
8
Output 4 Return
Table 10 Parallel Output connections.