Serial and Ethernet Control Page 154
Example: Send Command: 1ID<0D>
Response: R<0D>
IP Get/Set IP address
Description: This command will get or set the selected port IP address. Port A or B may be
selected
Comments: Where xxx is a decimal number in the range of 0 255.
Get command: (A or B)IP<0D>
Message Response: xxx.xxx.xxx.xxx<0D>
Example: Send Command: AIP<0D>
Response: 192.168.0.254<0D>
Set command: xxx.xxx.xxx.xxx(A or B)IP<0D>
Message Response: R<0D>
Example: Send Command: 192.168.0.254AIP<0D>
Response: R<0D>
SM Get/Set Subnet Mask number
Description: This command will get or set the number used to isolate the subnet.
Comments: xxx is a decimal number in the range of 0 255.
Get command: SM<0D>
Message Response: xxx.xxx.xxx.xxx<0D>
Example: Send Command: SM<0D>
Response: 255.255.255.0<0D>
Set command: xxx.xxx.xxx.xxxSM<0D>
Message Response: R<0D>
Example: Send Command: 255.255.255.0SM<0D>
Response: R<0D>
GW Get/Set Gateway IP Address
Description: This command will get or set the IP address of the gateway the unit will connect
through.
Comments: xxx is a decimal number in the range of 0 255.
Get command: GW<0D>
Message Response: xxx.xxx.xxx.xxx<0D>

Table of Contents