Serial and Ethernet Control Page 168
HP Get/Set the HTTP WEB Page
Description: This command will get or set the default HTTP WEB address.
Comments: The default WEB page is index.html
Get command: HP<0D>
Message Response: (currentwebpage)<0D>
Example: Send Command: HP<0D>
Response: myWebPage.html<0D>
Set command: (myWebPage.html)HP<0D>
Message Response: R<0D>
Example: Send Command: myWebPage.htmlHP<0D>
Response: R<0D>
RI Get/Set Redundant IP Address
Description: This command will get or set the Redundant IP address.
Comments: “x” represents a number in the IP.
Get command: RI<0D>
Message Response: (xxx.xxx.xxx.xxx)<0D>
Example: Send Command: RI<0D>
Response: xxx.xxx.xxx.xxx<0D>
Set command: (xxx.xxx.xxx.xxx)RI<0D>
Message Response: R<0D>
Example: Send Command: xxx.xxx.xxx.xxxRI<0D>
Response: R<0D>
RX Get/Set Redundant Ethernet Jack
Description: This command will get or set the Redundant Ethernet Jack.
Comments: “n” represents either A or B
Get command: RX<0D>
Message Response: (n)<0D>
Example: Send Command: RX<0D>
Response: A<0D>
Set command: (n)RX<0D>
Message Response: R<0D>