Integrated Master - NetLinx Programming
223
Enova Digital Media Switchers - Hardware Reference Manual
DXLink SEND_COMMANDs (Cont.)
Command Description
?DXLINKIN_QUALITY Requests a value that represents the quality of the signal between an Input Port and an Endpoint.
Syntax:
SEND_COMMAND <DEV>,"'?DXLINKIN_QUALITY'"
Example:
SEND_COMMAND INPUT_1,"'?DXLINKIN_QUALITY'"
Returns a COMMAND string of the form:
DXLINKIN_QUALITY--22
?DXLINKOUT_QUALITY Requests a value that represents the quality of the signal between an Output Port and an Endpoint.
Syntax:
SEND_COMMAND <DEV>,"'?DXLINKOUT_QUALITY'"
Example:
SEND_COMMAND OUTPUT_1,"'?DXLINKOUT_QUALITY'"
Returns a COMMAND string of the form:
DXLINKOUT_QUALITY--22
?DXLINKIN_QUALITY_ALARM Alarm is triggered when cable quality is beyond the threshold where overall performance issues are
likely to occur.
Syntax:
SEND_COMMAND <DEV>,"'?DXLINKIN_QUALITY_ALARM'"
Example:
SEND_COMMAND INPUT_1,"'?DXLINKIN_QUALITY_ALARM'"
Returns a COMMAND string of the form:
DXLINKIN_QUALITY_ALARM-OFF or DXLINKIN_QUALITY_ALARM-ON
?DXLINKOUT_QUALITY_ALARM Alarm is triggered when cable quality is beyond the threshold where overall performance issues are
likely to occur.
Syntax:
SEND_COMMAND <DEV>,"'?DXLINKOUT_QUALITY_ALARM'"
Example:
SEND_COMMAND OUTPUT_1,"'?DXLINKOUT_QUALITY_ALARM'"
Returns a COMMAND string of the form:
DXLINKOUT_QUALITY_ALARM-OFF or DXLINKOUT_QUALITY_ALARM-ON
?VIDIN_AUTO_SELECT Requests setting for the Auto Select mode for the input signal addressed by the D:P:S. VIDIN_AUTO
commands for Solecis Switchers must be sent directly to the Solecis unit, not sent via the 5002 device.
Syntax:
SEND_COMMAND <dev>, "'?VIDIN_AUTO_SELECT'"
Example:
SEND_COMMAND <5002:1:1>, "'?VIDIN_AUTO_SELECT'"
Returns a COMMAND string of the form:
VIDIN_AUTO_SELECT-<ENABLE|DISABLE>
VIDIN_AUTO_SELECT Enables or disables the Auto Select mode for the input signal addressed by the D:P:S. VIDIN_AUTO
commands for Solecis Switchers must be sent directly to the Solecis unit, not sent via the 5002 device.
Syntax:
SEND_COMMAND <dev>, "'VIDIN_AUTO_SELECT-<setting>'"
Variable:
• Setting = ENABLE or DISABLE
Example:
SEND_COMMAND <5002:1:1>, "'?VIDIN_AUTO_SELECT-ENABLE'"
?VIDIN_HSHIFT Requests the input horizontal shift of the specified VGA video port.
Syntax:
SEND_COMMAND <DEV>,"'?VIDIN_HSHIFT'"
Example:
SEND_COMMAND VIDEO_INPUT_1,"'?VIDIN_HSHIFT'"
Returns a COMMAND string of the form:
VIDIN_HSHIFT-<value>
VIDIN_HSHIFT Sets the horizontal shift of the specified video port to <value>.
Syntax:
SEND_COMMAND <DEV>,"'VIDIN_HSHIFT-<value>'"
Variable:
• value = -50 to 50
Example:
SEND_COMMAND <DEV>,"'VIDIN_HSHIFT-2'"
Sets the Horizontal shifting of VGA video input port (#1 based on D:P:S) to 2 (shift to right).
SEND_COMMAND VIDEO_INPUT_1,"'VIDIN_HSHIFT--3'"
Sets the horizontal shifting of VGA video input port (#1 based on D:P:S) to -3 (shift to left).

Table of Contents

Other manuals for AMX Enova DGX 100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMX Enova DGX 100 Series and is the answer not in the manual?

AMX Enova DGX 100 Series Specifications

General IconGeneral
BrandAMX
ModelEnova DGX 100 Series
CategorySwitch
LanguageEnglish

Related product manuals