Appendix A - Adding or Replacing Boards
243
Enova Digital Media Switchers - Hardware Reference Manual
11. Attach cables to the board’s connectors and reconnect any other cables that were disconnected in Step 3
Tie cables to cable management bars (if applicable).
 If the enclosure was powered down – Reapply power.
NOTE: For cabling information, see the specific board chapter in this manual.
12. Optional – If you have custom board settings to load to the board, use the System Configuration interface to load
them now (see page 184).
13. Execute a test switch using a connection on the new board to be sure that video is present at the destination
(Control Panel: press Function key, Select key, Input key, Output key, and Take key). See the Executing a Test
Switch section on page 70 for details.
Additional testing for Audio Insert/Extract Board functionality:
Insert function – If the DIP switch for the audio connector is set to insert, the video signal from the corresponding
video input or output will carry the inserted audio; check that the inserted audio is present with the display.
Extract function – If the DIP switch for the audio connector is set to extract, the audio will be extracted from the
corresponding video input or output signal; check the auxiliary or supplemental audio equipment involved to be
sure the extracted audio signal is present where expected.
NOTE: If the test switch does not work, see the Board Troubleshooting section on page 243.
IMPORTANT: If for any reason a board slot is left empty, be sure to attach a blank plate to cover it.
14. Enova DGX 3200 only – Replace connector numbering plate removed in Step 2.
Board Troubleshooting
Problems with Board Power Up
To verify that all I/O boards have been powered up after hot-swapping, enter ~scri6v3! in a terminal emulation program
and verify that none of the boards report an alarm.
If an alarm is reported, the board must be manually powered back up using the DGX_SHELL command power ON BCPUx
where x is the slot number of the board (for additional information on DGX_SHELL commands, see page 247.
NOTE: A complete list of the DGX_SHELL targets, BCPUx, is in the "Product to Board Slot Correspondence" table on
page 248.

Table of Contents

Other manuals for AMX Enova DGX 100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMX Enova DGX 100 Series and is the answer not in the manual?

AMX Enova DGX 100 Series Specifications

General IconGeneral
BrandAMX
ModelEnova DGX 100 Series
CategorySwitch
LanguageEnglish

Related product manuals