Parameter Description
When enabled, the device retrieves the Web user’s login
username from the smart card, which is automatically displayed
(read-only) in the Web Login screen; the user is then required to
provide only the login password.
Typically, a TLS connection is established between the smart
card and the device’s Web interface, and a RADIUS server is
implemented to authenticate the password with the username.
Thus, this feature implements a two-factor authentication - what
the user has (the physical card) and what the user knows (i.e.,
the login password).
http-port
[HTTPport]
Defines the LAN HTTP port for Web management. To enable
Web management from the LAN, configure the desired port.
The default is 80.
Note: For the parameter to take effect, a device reset is required.
[DisableWebConfig] Determines whether the entire Web interface is read-only.
[0] = (Default) Enables modifications of parameters.
[1] = Web interface is read-only.
When in read-only mode, parameters can't be modified and the
following pages can't be accessed: Web User Accounts, TLS
Contexts, Time and Date, Maintenance Actions, Load Auxiliary
Files, Software Upgrade Wizard, and Configuration File.
Note: For the parameter to take effect, a device reset is required.
[ResetWebPassword] Enables the device to restore the default management users:
Security Administrator user (username "Admin"; password
"Admin")
Monitor user (username "User"; password "User")
In addition, all other users that may have been configured (in the
Local Users table) are deleted.
[0] = (Default) Disabled. Currently configured users
(usernames and passwords) are retained.
[1] = Enabled. Default users are restored (see description
above) and all other configured users are deleted..
Note:
For the parameter to take effect, a device reset is required.
In addition to the ini file (see above), you can also restore the
default user accounts through the following management
platforms:
SNMP (restores default users and retains other
configured users):
1) Set acSysGenericINILine to
WEBPasswordControlViaSNMP = 1, and reset the device
with a flash burn (set acSysActionSetResetControl to 1
and acSysActionSetReset to 1).
2) Change the username and password in the
acSysWEBAccessEntry table. Use the following format:
Username acSysWEBAccessUserName: old/pass/new
Password acSysWEBAccessUserCode:
[WelcomeMessage] Enables and defines a Welcome message that appears on the