Release 9si/10si/Communication Manager 1.x to Communication Manager 2.1
Task list: R9si/10si/Communication Manager 1.x to Communication Manager 2.1
50 SI Installation and Upgrades
June 2004
Shut down DEFINITY AUDIX system
Return to Task List
A yellow caution sticker on the system’s power unit notifies you to shut down the AUDIX before
powering down the system.
!
WARNING:
Neglecting to shut down an AUDIX assembly before powering down the system cabinet
where it resides can damage the AUDIX disk.
1 Log into the AUDIX as craft.
NOTE:
If you have a dadmin login and password, you can use them instead of craft and the craft
password.
2 Type reset system shutdown and press Return.
3 Press Return again to start the shutdown.
The
SHUTDOWN Completed message appears when the AUDIX is successfully shutdown. This
takes about 2 minutes.
!
WARNING:
If you are leaving the AUDIX System in the carrier, back it out about 2 in. (5 cm) to
eliminate the possibility of damage due to power surges.
Return to Task List
Determine active SPE
NOTE:
Perform this procedure on high and critical reliability systems.
Return to Task List
1 Type status system 1 and press Return.
2 Determine which side is the active SPE.
3 The standby side should be in the standby state.