Install and Administer Trunks
Add DS1 Tie and OPS Trunks
672 SI Installation and Upgrades
June 2004
Disable Scheduled Maintenance and Alarm
Origination
to INADS (DS1 Tie and OPS Trunks)
Return to Task List
1 To prevent scheduled daily maintenance from interfering with the update or upgrade, type
change system-parameters maintenance and press Enter.
2 If scheduled maintenance:
— has begun: set the
Stop Time field to 1 minute after the current time.
— has not begun: set the
Start Time field to at least 8 hours after the upgrade starts.
CAUTION:
If you do not disable Alarm Origination, the system may generate alarms, resulting in
unnecessary trouble tickets.
3 Type neither in the Alarm Origination to OSS Numbers field and press Enter.
Return to Task List
Save Translations (DS1 Tie and OPS Trunks)
Return to Task List
1 If the system is high or critical reliability, type status system 1 and press Enter to verify that the
system is in the
active/standby mode.
2 Type save translation and press Enter. This instructs the system to take all translation
information in memory and write it to the translation card or removable media.
3 If the system contains a TN750/B Announcement circuit pack, type display announcements and
press Enter. If administered recorded announcements are listed, type
list configuration
software-version
press Enter. Check Page 2 of this form to see when the announcements were
last saved. To save the current announcements, type
save announcements and press Enter.
Shut Down DEFINITY LAN Gateway System
(DS1 Tie and OPS Trunks)
Return to Task List
!
WARNING:
Neglecting to shut down the LAN Gateway assembly before powering down the system
cabinet can damage the LAN Gateway disk.
1 Log onto the DEFINITY LAN Gateway.
2 From the main menu, click Maintenance > Reset System > Shutdown.