EasyManua.ls Logo

Avaya MCC1 - New Duplicated G3 R Installations Only; New Simplex and Upgraded G3 R Only

Avaya MCC1
874 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Install Additional Hardware
Task List: Add DCS
596 SI Installation and Upgrades
June 2004
The TN799x C-LAN circuit pack is now installed in the DEFINITY carrier and connected to the IP
network.
Return to Task List
Deliver License File (Add DCS)
Return to Task List
CAUTION:
This procedure must be done immediately after you upgrade the software. If the license
file is not installed within 10 days, the switch enters a No-License mode and shuts down
all call processing.
New Duplicated G3r installations only
1 Retrieve the RFA License File with both serial numbers from the RFA Application.
2 Type set time and press Enter.
Ensure that the system date and time are set correctly.
3 Use one of these installation methods:
Direct connection between the switch and RFA
No connection between the switch and RFA
4 Type save translation and press Enter.
After the translations have been copied (about 10 minutes), the system returns an error code,
which must be a zero; otherwise, the translations are not copied.
5 Type reset system 4 and press Enter.
Wait until the system has completely reset before continuing.
6 Type change cabinet 1 and press Enter.
In the
Carrier Type column change the “B” carrier to processor and submit the form.
7 Type change system-parameters duplication and press Enter.
Set the
Enable Operation of SPE Duplication field to y and submit the form.
8 Type save translation and press Enter.
After the translations have been copied (about 10 minutes), the system returns an error code,
which must be a zero; otherwise, the translations are not copied.
9 Type reset system 3 preserve-license (or reset system 3 no-preserve-license, since the
License File has been saved in translations) and press Enter.
New simplex and upgraded G3r only
1 Type save translation and press Enter.
After the translations have been copied (about 10 minutes), the system returns an error code,
which must be a zero; otherwise, the translations are not copied.
2 Type reset system 3 and press Enter.
Wait until the system has completely reset before continuing.