G3iV4 to Avaya Communication Manager
Task List: G3iV4 to Avaya Communication Manager
86 SI Installation and Upgrades
June 2004
5 Type list signaling-group and press Enter. For each signal, execute status signal <number>.
Validate that all the signal groups that should be operational are in service.
6 Execute the following commands and verify that the information is correct:
list station
list trunk-group
list hunt-group
list data-module
For upgrades from systems later than G1, list ars analysis
For a system with Expert Agent later than G3V3,
list agent
7 For duplicated systems only, execute status system 1
Return to Task List
Check customer options [from G3V4]
Return to Task List
High or Critical Reliability
1 Verify that the switches are in auto: Type status system 1 and press Enter.
Verify that conditions are normal (this can take as long as 5 to 10 minutes). If the system refuses
to go onto a normal condition, refer to the maintenance procedures; if that fails, escalate the
problem.
All
1
Type display system-parameters customer-options and press Enter.
Check that the
G3 version: field is V11.
Restore busyouts [from G3V4]
Return to Task List
1 Restore any busyouts that you removed in the Verify system status [from G3V4] section prior to
the upgrade.