5 Type reset system 4 and press Enter.
Wait until the system has completely reset before continuing.
6 Type change cabinet 1 and press Enter.
In the
Carrier Type column change the “B” carrier to processor and submit the form.
7 Type change system-parameters duplication and press Enter.
Set the
Enable Operation of SPE Duplication field to y and submit the form.
8 Type save translation and press Enter.
After the translations have been copied (about 10 minutes), the system returns an error code,
which must be a zero; otherwise, the translations are not copied.
9 Type reset system 3 preserve-license (or reset system 3 no-preserve-license, since the
License File has been saved in translations) and press Enter.
New simplex and upgraded G3r only
1 Type save translation and press Enter.
After the translations have been copied (about 10 minutes), the system returns an error code,
which must be a zero; otherwise, the translations are not copied.
2 Type reset system 3 and press Enter.
Wait until the system has completely reset before continuing.
3 If the system has IP endpoints registered, unplug the Ethernet cable from the TN799 (C-LAN)
circuit pack.
This disconnects (unregisters) all IP endpoints.
4 Type set time and press Enter.
Ensure that the system date and time are set correctly.
5 Use one of these installation methods:
Direct connection between the switch and RFA
No connection between the switch and RFA
New or upgraded G3si only
1 Retrieve the RFA License File with both serial numbers from the RFA Application.
2 If the system has IP endpoints registered, unplug the Ethernet cable from the TN799 (C-LAN)
circuit pack.
This disconnects (unregisters) all IP endpoints.
3 Type set time and press Enter.
Ensure that the system date and time are set correctly.
4 For duplicated systems only type status system all and press Enter.
Ensure that the standby SPE is not in the maintenance state. If it is, wait for the maintenance state
to finish.
5 Use one of these installation methods:
Direct connection between the switch and RFA
No connection between the switch and RFA