© Brüel & Kjaer Vibro ● S1079330.002 / V04 ● █ Page 157 of 188
Technical alterations reserved!
Brüel & Kjaer Vibro │ Instruction
VC-8000 MPS
Content
EN
23.7.2 Update Firmware
Be aware– This procedure may trip relays. Do not perform this procedure unless all relays are
externally bypassed, or the machine is down.
Follow these steps to update the firmware on all modules:
Important!
• Externally bypass the rack (trips) and notify operations that data will be temporarily lost, relays may
change state, and the OK relay may change state.
• Install the latest version of VC-8000 MPS Software to get the latest updates.
Connect to the rack.
Select the Firmware Upgrade Tab.
Review the information and select modules to
update.
Select Apply to update the firmware.
The firmware update window will appear.
Note: Firmware updates can take up to 20
minutes for large racks.