Page 180 of 188
█ © Brüel & Kjaer Vibro ● S1079330.002 / V04
Technical alterations reserved
EN
24.11.3 Diff Exp Single Probe
Typical uses: Steam turbine single probe differential expansion
Measurement Description Default or Add
Differential Expansion position.
DC sensor Gap voltage for diagnostics.
24.11.4 Diff Exp Comp Input
Typical uses: Steam Turbine Complementary Input Differential Expansion
Measurement Description Default or Add
Composite
Differential expansion measurement combining the
measurements from sensors 1 and 2 to double the available
Position measurement from sensor 1.
Position measurement from sensor 2.
DC sensor 1 Gap voltage for diagnostics.
DC sensor 2 Gap voltage for diagnostics.
24.11.5 Diff Exp Dual Ramp
Typical uses: Steam turbine dual ramp differential expansion
Measurement Description Default or Add
Composite
The differential expansion measurement using two probes
to eliminate common errors.
The position measurement for sensor 1.
The position measurement for sensor 2.
DC sensor 1 Gap voltage for diagnostics.
DC sensor 2 Gap voltage for diagnostics.
24.11.6 Diff Exp Single Ramp
Typical uses: Steam turbine single ramp differential expansion
Measurement Description Default or Add
Composite
The differential expansion measurement using two probes
to eliminate common errors.
The position measurement for sensor 1.
The position measurement for sensor 2.
DC sensor 1 Gap voltage for diagnostics.
DC sensor 2 Gap voltage for diagnostics.