Page 178 of 188
█ © Brüel & Kjaer Vibro ● S1079330.002 / V04
Technical alterations reserved
EN
24.9.5 Tracking REB Acceleration (Recommended)
Typical uses: Rolling Element Bearings using an accelerometer on a variable speed machine (up to
4500 rpm). This channel type can only be selected in channels 1 through 3.
Measurement Description Default or Add
Overall
Overall dynamic amplitude measurement.
24 dB/octave (4 pole) roll-on, -24 dB/octave (4 pole) roll-off.
DC sensor bias voltage for diagnostics.
1X amplitude
A synchronous amplitude and phase measurement at
running speed.
PT required
Cage
Envelope demodulated and tracking filtered amplitude.
PT required
IRBP
Envelope demodulated and tracking filtered amplitude.
PT required
ORBP
Envelope demodulated and tracking filtered amplitude.
PT required
Ball Spin
Envelope demodulated and tracking filtered amplitude.
PT required
2X Ball Spin
Envelope demodulated and tracking filtered amplitude.
PT required
Asynchronous and Peak-Stretch (enveloping)
24.10 Rotation and Speed
VC-8000 speed channels are not suitable for over-speed protection.
24.10.1 Reverse Rotation
Typical uses: Determine shaft rotation direction using two Phase Trigger inputs.
Measurement Description Default or Add
Rev Speed
Reverse Speed. The current measured speed in the
reverse direction.
Num Rev
Rotations
Number of Reverse Rotations. A cumulative count of the
number of rotations in the reverse direction. Reset using
the peak hold reset button.
Rev Peak
Speed
Reverse Peak Speed. Holds the maximum speed read in
the reverse direction. Reset using the peak hold reset
Forward speed reading for the first sensor.
DC sensor Gap voltage for diagnostics.
DC sensor Gap voltage for diagnostics.