If you are using an OSI Soft PI System, the CMS Navigation Path is imported into the PI Asset
Framework (AF) database. After the initial instance is created, the user can modify the AF database
(using OSI Soft PI tools) if needed.
13.2.4 Synchronous Waveforms
Synchronous Waveform data collection is configured in terms of the number of samples collected per
shaft revolution, evenly spaced in phase. Higher sample rates give better Orbit and Timebase plot
resolution, but more coarse resolution for spectrums displayed in orders. More samples (or
revolutions) take longer to collect and provide greater spectrum resolution. The collection time of
synchronous waveforms is dependent on the speed of the machine.
Rate
Maximum
Number of
Revolutions
Spectrum
Spectrum
128X
64X
32X
16X
Table 13-5) Synchronous Sampling Configuration Examples
13.2.5 Asynchronous Waveforms
Synchronous Waveform data collection is configured in terms of the number of samples collected per
shaft revolution, evenly spaced in phase. Higher sample rates give better Orbit and Timebase plot
resolution, but more coarse resolution for spectrums displayed in orders. More samples (or
revolutions) take longer to collect and provide greater spectrum resolution. The collection time of
synchronous waveforms is dependent on the speed of the machine.
Samples per Second Span Samples (Lines) Resolution Time to Collect
256
512
1280
2560
5120
1280
25600
51200
Table 13-6) Asynchronous Sampling Configuration Examples