MAX Operation & Service Manual 119MAX Operation & Service Manual Section 6: Maintenance & Service 119
Replacing/Cleaning the Cleaner Screen Filter
Parts needed: Cleaner lter - screen only, 40-mesh, part number 11-655024-004 or complete lter
assembly with ttings, part number 14-100478-000.
Tools needed: spare container, 3/8” open ended wrench or socket.
Refer to Figure6-15.
1. Place machine in operating position with covers open.
2. Disconnect power to the machine and the cable assembly attached to the Cleaner Pump.
3. Slowly disconnect the tubing from the top of the lter. Once air is introduced into the tubing
the cleaner will ow back into the tank.
4. Loosen the two bolts at the top of the pump and lter assembly that secure it to the rear frame
and lift out the cleaner pump and lter bracket.
5. Disconnect the return tubing from the cleaner supply tank tting. Move the pump and lter
bracket to the top of the cleaner supply tank.
6. Remove the cleaner tank cap and route the tubing from the lter assembly into the neck of the
tank and allow as much uid from the lter assembly to drain into the tank.
7. Remove the cap of the strainer assembly and remove the mesh strainer.
8. Clean the lter/strainer by running under water or replace, if necessary. (a spare strainer is
located in the spare parts kit)
9. Replace strainer and bowl, take care to ensure the strainer is on straight, not crushed, and the
bowl gasket is properly positioned around the entire groove of the lter body.
10. Reconnect the supply tubing as you replace the pump and lter bracket in the machine, tighten
the bolts.
11. Reconnect the pump power and ground cables, and restore power to the machine.
12. Place machine on the lane and turn on the cleaner pump via the “Cleaner Diagnostics” screen in
the “Maintenance” menu of the Tablet. This will prime the system removing air.
13. Set the cleaner pressure to 18 psi as it may measure a higher pressure reading with the cleaned
or new mesh strainer.
14. Test clean one or more lanes (as needed) to verify that all air has been purged from the cleaning
system.
NOTE:Totestthecleaningperformancesetthepatterntoa“Clean”modeinthe“Design”,
“PatternParameters”inthe“Pattern”menu.