120 MAX Operation & Service Manual120 Section 6: Maintenance & Service MAX Operation & Service Manual
Adjusting the Cleaner Pressure
Tools needed: none.
Adjustment: 17 - 19 psi.
Refer to
Figure6-15.
1. Place the machine in the operator position and supply power.
2. Place the machine on the lane and open the two top covers.
3. Navigate to “Cleaning”, “Diagnostics” in the “Maintenance” menu.
4. Turn on the Cleaner Pump paying attention to the pressure reading on the Tablet.
5. Rotate the pressure control valve knob on the cleaner manifold assembly, clockwise to increase
the system pressure.
6. Turn the pressure control valve knob on the cleaner manifold assembly, counter-clockwise to
decrease the system pressure.
7. Secure the pressure valve setting knob by tightening the top set screw.