124 MAX Operation & Service Manual124 Section 6: Maintenance & Service MAX Operation & Service Manual
Replacing the Level Float Sensor in Conditioner Supply Tank
Tools Needed: 3/8” open ended wrench or socket, 1/8” Allen wrench
Parts needed: Replacement Level Float Sensor, part number 14-100942-000.
Refer to
Figure6-17.
1. Drain the conditioner supply tank. (Refer to draining the conditioner supply tank.)
2. Remove the battery clamps with the 1/8” Allen wrench.
3. Turn off bower and disconnect the battery cable from the electronic enclosure, then remove the
batter y.
4. Disconnect all tubing at conditioner tank.
5. Disconnect cable from level oat sensor.
6. Remove the 4 mounting screws for the frame support next to the oil tank.
7. Remove tank by loosening (2) support bolts and lifting tank out of the machine.
8. Remove faulty sensor from the tank using a 1” and 3/8” wrench, turning counter-clockwise to
loosen the sensor compression nut.
9. Insert the new sensor with the indicator pointing toward the top of the tank and tighten.
NOTE:Sensoriscorrectlypositionedifthewhiteoathangsdowntowardthebottomofthe
tankwhenmachineisintheoperatingposition.
10. Replace tank into machine and tighten mounting bolts.
11. Replace the frame support with the 4 mounting screws.
12. Reconnect sensor cable.
13. Reconnect tubing at tank.
14. Fill the conditioner supply tank to verify that there is no leaking from around the new level
sensor.