136 MAX Operation & Service Manual136 Section 6: Maintenance & Service MAX Operation & Service Manual
18. Replace the buffer lifting motor assembly and fasten the three screws with the 3/8” wrench.
19. Connect the buffer lift connecting link to the cam through the access hole in the left hand side
frame and tighten with the 3/16” Allen wrench.
20. Connect the cable assembly to the buffer lifting motor assembly.
21. Replace the conditioner tank with the two screws and tighten with the 3/8” wrench.
22. Connect the tubing to the tank and level oat sensor to the cable harness.
23. Lithium Battery: Install the battery into the tray with battery cable closest to the electronic
enclosure.
24. Replace the battery clamps with the four screws and fasten with the 1/8” Allen wrench.
25. Replace the left hand top cover with the six screws and tighten with the #2 Phillips screwdriver.
26. Connect the gas spring (no tools needed).
27. Connect the battery cable and power type jumper to the electronic enclosure and turn on the
main power switch on the left hand side cover.
Lubricating the Buffer Brush Bearings
Refer to Figure6-22.
1. Attach grease gun to the grease tting located on the wall mounted buffer bearing.
2. Squeeze gun twice.
3. Repeat for the opposite side.
Lubricating the Buffer Brush Lifting Assembly
Refer to Figure 6-22.
1. Apply one drop of oil to the bearings in the buffer brush lifting linkages on 7 and 10-pin sides.