EasyManua.ls Logo

Canon MVX200 E - Trouble Shooting; Power Supply

Canon MVX200 E
259 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MVX250i E, MVX200i E, MVX200 E
SERVICE HINTS
5
2. Trouble Shooting
To detect the failure part for repair, if any, use the following hints and check points.
2-1 Power Supply
<Hints>
When the power source is attached, the unit enters the standby mode in the following sequences.
Main power is connected. UNREG is supplied to the MAIN P.C.B. MODE MI-COM starts up. MODE MI-COM outputs VCR
ON “H” signal. PWM driver starts up and turns on each power supply. Establishes communication with the FR MI-COM. FR
MI-COM initializes recorder mechanical chassis. After initialized, the MODE MI-COM is brought into the standby status with the
VCR ON changed to VCR Low.
After that, the power supply is turned ON by the following procedures.
Power supply mode switch operation After MODE MI-COM is accepted, VCR ON “H” is output. The PWM driver is started to
turn on various power supplies. The FR MI-COM is started to control the system.
<Check Points>
1) Key Inputs
Check the key inputs at Powe r Switch in the SERVICE mode.
2) Check of microcomputer-to-microcomputer communication
If the microcomputer-to-microcomputer communication line is normal, the version number of each microcomputer can be indi-
cated in the service mode. Otherwise, the communication line or microcomputer may be faulty.
3) Error in Mechanism (“SERVICE MODE · ADJUSTMENT” P. 9)
If any error is occurred by mechanism trouble at initializing, the error can be detected.
At this state, the power can be turned on, but the unit enters “ERROR STOP” state. In this case, check the error data in the
SERVICE mode.
4) VCR O N “H”, CAM ON “H” (control signal from MODE MI-COM) Outputs
Check the output of control signal.
5) Fuses on the POWER SUPPLY P.C.B.
Check the continuity of the fuses FU3201, 3202, 3203, 3205 and 1801 on the MAIN P.C.B. In case of NG, replace the fuse and
check the power consumption.
6) Replace the MAIN P.C.B. with a service part and check the operation.

Table of Contents

Related product manuals