EasyManua.ls Logo

Ceragon FA4800 - Page 283

Ceragon FA4800
329 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IDU (all models) Alarm Connector Appendix B
FA4800 User Manual Release 1.9.40 B-4
The figure below, shows how to connect external input and output alarms.
Figure B-1: Example for connecting the alarm connector
Output 3 Normally Open 7
Output 3 Common 8
Output 3 Normally Closed 9
Output 4 Normally Open 10
Output 4 Common 11
Output 4 Normally Closed 12
Note
Use an external current limit resistor to limit the current at the output
relays to 1 Amp. Such resistor is not required if the equipment con-
nected to the IDU supports current limiting to 1 Amp.
The voltage of the input alarm must be within the range of -10 to -50
VDC.
Table B-7: IDU Alarm Connector (Dry-Contact) (Continued)
I/O Description Pin

Table of Contents