EasyManua.ls Logo

Ceragon FA4800 - Page 299

Ceragon FA4800
329 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MIB Parameters Appendix D
FA4800 User Manual Release 1.9.40 D-14
fibeAir4800OduPerfMonDayUAS RO The current number of Unavailable Seconds per
interval of 24 hours.
fibeAir4800OduPerfMonDayES RO Current number of Errored Seconds per interval of
24 hours.
fibeAir4800OduPerfMonDaySES RO Current number of Severely Errored Seconds per
interval of 24 hours.
fibeAir4800OduPerfMonDayBBE RO Current number of Background Block Errors per
interval of 24 hours.
fibeAir4800OduPerfMonDayIntegrity RO Indicates the integrity of the entry per interval of 24
hours.
fibeAir4800OduPerfMonAirCurrTable N/A This table defines/keeps the air counters of the
current 15 min interval.
fibeAir4800OduPerfMonAirCurrEntry N/A This is an entry in the Current Interval Table.
INDEX {ifIndex }
fibeAir4800OduPerfMonAirCurrMinRSL 1.3.6.1.4.1.4458.1000.1.6.4.1.1 Integer RO Current Min Received Level Reference starting
from the present 15 minutes period.
fibeAir4800OduPerfMonAirCurrMaxRSL 1.3.6.1.4.1.4458.1000.1.6.4.1.2 Integer RO Current Max Received Level Reference starting
from the present 15 minutes period.
fibeAir4800OduPerfMonAirCurrRSLThresh1Ex
ceed
1.3.6.1.4.1.4458.1000.1.6.4.1.3 Gauge RO Number of seconds Receive Signal Level
exceeded the RSL1 threshold in the last 15
minutes.
fibeAir4800OduPerfMonAirCurrRSLThresh2Ex
ceed
1.3.6.1.4.1.4458.1000.1.6.4.1.4 Gauge RO Number of seconds Receive Signal Level
exceeded the RSL2 threshold in the last 15
minutes.
fibeAir4800OduPerfMonAirCurrMinTSL 1.3.6.1.4.1.4458.1000.1.6.4.1.5 Integer RO Current Min Transmit Signal Level starting from
the present 15 minutes period.
fibeAir4800OduPerfMonAirCurrMaxTSL 1.3.6.1.4.1.4458.1000.1.6.4.1.6 Integer RO Current Max Transmit Signal Level starting from
the present 15 minutes period.
fibeAir4800OduPerfMonAirCurrTSLThresh1Ex
ceed
1.3.6.1.4.1.4458.1000.1.6.4.1.7 Gauge RO Number of seconds Transmit Signal Level
exceeded the TSL1 threshold in the last 15
minutes.
fibeAir4800OduPerfMonAirCurrBBERThresh1
Exceed
1.3.6.1.4.1.4458.1000.1.6.4.1.8 Gauge RO Number of seconds Background Block Error Ratio
exceeded the BBER1 threshold in the last 15
minutes.
fibeAir4800OduPerfMonAirIntervalTable N/A This table defines/keeps the air counters of the last
day (in resolution of 15 min intervals).
fibeAir4800OduPerfMonAirIntervalEntry N/A This is an entry in the Interval Table. INDEX
{ifIndex fibeAir4800OduPerfMonAirIntervalIdx }
fibeAir4800OduPerfMonAirIntervalIdx RO This table is indexed per interval number. Each
interval is of 15 minutes and the oldest is 96.
fibeAir4800OduPerfMonAirIntervalMinRSL RO Current Min Received Level Reference per
interval.
fibeAir4800OduPerfMonAirIntervalMaxRSL RO Current Max Received Level Reference per
interval.
fibeAir4800OduPerfMonAirIntervalRSLThresh1
Exceed
RO Number of seconds Receive Signal Level
exceeded the RSL1 threshold per interval.
fibeAir4800OduPerfMonAirIntervalRSLThresh2
Exceed
RO Number of seconds Receive Signal Level
exceeded the RSL2 threshold ACCESS read-
only per interval.
fibeAir4800OduPerfMonAirIntervalMinTSL RO Current Min Transmit Signal Level per interval.
fibeAir4800OduPerfMonAirIntervalMaxTSL RO Current Max Transmit Signal Level per interval.
fibeAir4800OduPerfMonAirIntervalTSLThresh1
Exceed
RO Number of seconds Transmit Signal Level
exceeded the TSL1 threshold per interval.
fibeAir4800OduPerfMonAirIntervalBBERThres
h1Exceed
RO Number of seconds Background Block Error Ratio
exceeded the BBER1 threshold per interval.
Table D-2: Private MIB Parameters (Sheet 10 of 18)
Name OID Type
Access
Description

Table of Contents