List of ACU events
G-12 Appendix G: System messages 98-150471-A02
08840-0 ADM WARNING Master PLL lock The master PLL has lost lock. Check the input
reference signal.
09000-0 KDM ERROR KDM 3V3 supply Internal 3V3 voltage supply error in the KDM.
09001-0 KDM ERROR KDM 12V supply Internal 12V voltage supply error in the KDM.
09002-0 KDM ERROR KDM display Display hardware error in the KDM.
09010-0 KDM ERROR KDM link/SW
version
Link to the KDM module could not be established.
Either the KDM board is malfunctioning, or - if the
system software has just been updated - the
software is too old and is not compatible with the
KDM hardware.
0B000-0 PSM ERROR PSM production
data
Missing or invalid production data in the PSM.
Replace it.
0B001-0 PSM ERROR NMEA 2000
identifier
Missing or invalid production data in the PSM.
Replace it.
0B010-0 PSM ERROR PSM link/SW
version
Link to the PSM module could not be established.
Either the PSM board is malfunctioning, or - if the
system software has just been updated - the
software is too old and is not compatible with the
PSM hardware.
0B060-0 PSM WARNING NMEA 0183 parse
error
Parse errors detected on the NMEA 0183 interface.
Check NMEA 0183 cable, signal levels etc.
0B061-0 PSM WARNING Power supply
temperature
ACU Power supply temperature is high. Improve
ventilation or move to a cooler area. Info:
00000000 = Temperature warning, system still
operational, but will shut down eventually if
temperature keeps rising. 00000001 =
Temperature critical, system has shut down to
protect the hardware from overheating.
Error code
(ID)
Unit Severity Description Explanation
Table G-2: ACU event messages (Continued)
SAILOR900HP.book Page 12 Monday, July 18, 2016 12:44 PM