Configuration with the web interface
98-150471-A02 Chapter 6: Configuration 6-25
For modems communicating via Ethernet: Make sure that you have entered the
correct IP address also for the LAN connector that is used for the modem, see To
configure the LAN network on page 6-30.
5. Click Apply to add the new profile to the list of VSAT modem profiles or to accept the
edits.
10 MHz reference Select the 10 MHz reference source for the BUC/LNBs.
Recommended settings:
VMU-TX: STM Satlink 2900, Gilat SkyEdge II, COMTECH,
iDirect modems,
ACU Internal: service modem, InmarsatG5
RSSI lock type Select None (no RX lock), High (positive voltage) or Low
(negative voltage)
RSSI lock level Enter the voltage level for the modem RX lock signal.
Range: 0 - 14000 mV (-14 VDC to+ 14 VDC)
The SAILOR 900 VSAT High Power can work either using the Rx or Tx
10 MHz reference signals provided by the modem or using its own built-in
10 MHz reference signal. It is recommended to use the Tx 10 MHz
reference signal from the modem.
Parameter Description
Table 6-12: Modem configuration data (Continued)