Select Disable or Enable from the drop-down list. If enabled, the Scanner Master or
SC5000 Controller Input 3 status is echoed to the Ethernet Client via bit 2 in Byte
InputBits of the DL_InputStruct.
This parameter is configurable only if Start Input from Bus is enabled.
Select Disable or Enable from the drop-down list. If enabled, the Reading Phase
status is echoed to the Ethernet Client via bit 7 in Byte InputBits of the
DL_InputStruct.
ASI Object: On-Demand Options
NOTE: Contact Datalogic Support for information on setting up ASI Objects
(legacy Accu-Sort Devices). See Support Through the Website.
Enter the IP Address for the PLC Controller (Rockwell Automation: Allen-Bradley
Controllogix or CompactLogix).
Enter a tag name (up to 40 characters) in the field provided.
Enter the PLC Slot number in the field provided. This corresponds to the physical
slot used on the PLC.