EasyManuals Logo

Datalogic Magellan 800i Product Reference Guide

Datalogic Magellan 800i
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
Enter/Exit Programming Mode
Product Reference Guide
97
Minimum Reads
This feature specifies the minimum number of consecutive times an Interleaved
2 of 5 label must be decoded before it is accepted as good read.
006D01(CR)
Minimum = 1 Read
DEFAULT
Minimum = 2 Reads
006D02(CR)
006D03(CR)
Minimum = 3 Reads
Minimum = 4 Reads
006D04(CR)
Codabar
The following options apply to the Codabar symbology.
Disable/Enable Codabar
When this feature is disabled, the scanner will not read Codabar bar codes.
008F00(CR)
Disable Codabar
DEFAULT
Enable Codabar
008F01(CR)

Table of Contents

Other manuals for Datalogic Magellan 800i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 800i and is the answer not in the manual?

Datalogic Magellan 800i Specifications

General IconGeneral
Scanner type2D
Yaw reading angle-60 - 60 °
Decoding standardsGS1 DataBar, Aztec Code, Data Matrix, MaxiCode, QR Code, GS1 DataBar Expanded Stacked, GS1 DataBar Stacked, GS1 DataBar Stacked Omnidirectional, MicroPDF417, PDF417
Tilt reading angle0 - 360 °
Optical sensor resolution752 pixels
Light levels (direct sunlight)0 - 86000 lx
BluetoothNo
Cable length2 m
Standard interfacesUSB
Input voltage5 V
Power consumption350 mA
Dimensions (WxDxH)76 x 109 x 151 mm
CertificationChina RoHS EU RoHS
Product colorWhite
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Weight306.2 g

Related product manuals