Enter/Exit Programming Mode
Product Reference Guide
29
Interface Features
Obey/Ignore Host Commands
When set to ignore host commands, the scanner will ignore all host commands
except for the minimum set necessary to keep the interface active and transmit
labels For normal operation of the interface, select Obey Host Commands.
Obey Host Commands
DEFAULT
Ignore Host Commands
Host Transmission Buffers
Specifies the number of host transmission(s) that may be buffered. By buffering
data from a bar code, the scanner can continue to read a new bar code while
the old one is being transmitted to the host. Selecting BUFFERS = 1 means that
the first bar code must be transmitted before a new one can be read. A selec-
tion of BUFFERS = 2 means that
a new bar code can be read while data from the
first bar code is transmitted.
When a DISABLE SCANNER command is received from the host, the scanner will
co
ntinue to transmit all data that is buffered.
Host Transmission Buffers = 1
Host Transmission Buffers = 2
DEFAULT