Enter/Exit Programming Mode Standard 2 of 5
110 Magellan™ 800i Scanner
Length Control
Fixed Length Decoding — When fixed length decoding is enabled, the scanner
will decode a bar code if the label length matches one of the configurable fixed
lengths.
Variable Length Decoding — When variable length decoding is enabled, the scan-
ner will decode a bar code if the label length falls in the range of the configu-
rable minimum and maximum le
ngth.
049700(CR)
Variable Length Decoding
DEFAULT
Fixed Length Decoding
049701(CR)
Standard 2 of 5 Length 1, Length 2 Programming Instructions
See page 136for detailed instructions on setting this feature.
NOTE
0498(CR)
DEFAULT SETTING FOR THIS FEATURE: 08
Set Length 1
Set Length 2
0499(CR)
DEFAULT SETTING FOR THIS FEATURE: 50
For Standard 2 of 5 BAR CODES, all
check and data characters are included
in the length calculations.