Enter/Exit Programming Mode UPC-E
64 Magellan™ 800i Scanner
Number System Digit
The Number System Digit (NSD) which is always a zero (0) in the leading posi-
tion can be optionally included (or not) with
scanned bar code data.
024800(CR)
Exclude Number System Digit
Include Number System Digit
DEFAULT
024801(CR)
Expand to UPC-E to UPC-A
Enables/disables expansion of UPC-E labels to UPC-A. Selecting this feature
also changes the symbology ID to match those required for UPC-A.
004100(CR)
Don’t Expand UPC-E to UPC-A
DEFAULT
Expand UPC-E to UPC-A
004101(CR)
Expand UPC-E to EAN13
Enables/disables expansion of UPC-E labels to EAN-13. Selecting this feature
also changes the symbology ID to match those required for EAN-13.
040200(CR)
Don’t Expand UPC-E to EAN-13
DEFAULT
Expand UPC-E to EAN-13
040201(CR)